Product DescriptionAIREX TITAN OUTLET
– Professionally Engineered and with an Architectural aesthetic finish design, features a Wall Outlet Enclosure with excellent weather proofing capabilities that fits over and seals around wall surface piping penetrations, utilizing elastomeric gaskets and seals, as required by building, energy, and mechanical codes.
AIREX TITAN OUTLET
prevents wall gaps and exterior surface cracks associated with the use of rigid wall penetration sleeves or rigid penetration flashing materials. Featuring a combined fastener and gasket/seal applied compression-force system that accomplishes simultaneous, solid, internal wall structure attachment and all-surface wall gasket mounting for long-term sustainable and effective air leakage sealing.
An integral over-molded Flexible Elastomeric Sleeve, seals the refrigerant piping and insulation, creating an air leakage seal, that permanently supports the refrigerant piping at the point of equipment service areas, professionally engineered and with an architectural aesthetic finish design. The sleeve also features a designated region to accommodate a stainless-steel clamp that mechanically grips both refrigerant piping and piping insulation, mechanically securing against vibration, rodents, insects, and pipe insulation protection for outdoor usage.
Wall Surface Applications
Brick
Concrete
Masonry
Metal Paneling
Siding
Stone
Stucco
Drywall
Approved Product & Material Testing
ASTM E283
– Standard Test Method for Air Leakage
ASTM E331
– Standard Test Method for Water Penetration
ASTM D1525C-09
- Temperature Deformation Test
ASTM D648-07
- Temperature Load Deformation Test
ASTM D412
- Tension Deformation Test (UV Exposure & Water Immersion)
UL 94 HB
- Flammability Test
UL 746C
- Outdoor Suitability - f1 Rating
ASTM D573-04
- Deterioration Test
ASTM D746-07
- Brittleness Temperature Impact Test
Codes & Standards Compliance
IBC
- 2006, 2009, 2012 Chapter 13
IRC
- 2006, 2009, 2012 Chapter 11 Part IV Energy Efficiency - Section N1101 General - N1101.1 Scope - Air Leakage Section N1102.4 Section N1102.4.1 - Building Thermal Envelope - (1. All joints, seams, penetrations) Chapter 11 Refrigeration Section 1101.0 Scope -1101.3 Protection
IECC
- 2006, 2009, & 2012 Air Leakage (Mandatory) - Residential Section 402.4.1 and 402.4.1.1 Building Thermal Envelope – Penetrations
IECC
- 2006, 2009, & 2012 Air Leakage (Mandatory) - Commercial Section C402.4.3 and C402.4.2 Building Thermal Envelope – Penetrations
IMC
- 2006, 2009, & 2012 Chapter 3 General Regulations Section 301.1 Scope – Sections 301.10, 301.11, 301.14, 301.15, 305.1, 305.2, 305.4
UMC
- 2006, 2009, & 2012 Chapter 11 Refrigeration – Section 1101.0 Scope - Section 1101.1 - General Requirements Section 1106.0 – Section 1106.2, Section 1111.0 Erection of Refrigerant Piping – Sections 1111.1, 1111.2, 1111.4
California Building Energy Standards (Title 24)