Airex TITAN OUTLET WITH E-FLEX GUARD KIT- TGS-650W72CW Complete Kit
$ 31.67
- Description
- Size Guide
Description
Complete KIT Outlet with SleeveProduct Description
AIREX PRO-SYSTEM KIT™
is a 2-in-1 system for combined air-tight sealing wall-mounted piping outlets and UV/Vapor Retarder insulation protection system for exterior HVAC refrigerant piping penetrations and outdoor insulation located at the point of service connections for outdoor equipment.
The 2-In-1 System (Includes
TITAN OUTLET
and
E-FLEX GUARD
) Offers improved sustainability, energy efficiency, and optimum performance of building wall, outdoor pipe insulation, and HVAC equipment. Due to the multi-dimensional complexities of recent building energy codes, building codes, green codes, mechanical codes, residential codes, and standards within this category, using
AIREX PRO-SYSTEM KIT™
is the only guaranteed solution to meet all your quality needs and mandatory code requirements.
AIREX PRO-SYSTEM KIT combines the following products:
TITAN OUTLET
– Professionally Engineered and with an Architectural aesthetic finish design, features a Wall Outlet Enclosure with excellent weather proofing capabilities that fits over and seals around wall surface piping penetrations, utilizing elastomeric gaskets and seals, as required by building, energy, and mechanical codes. AIREX TITAN OUTLET prevents wall gaps and exterior surface cracks associated with the use of rigid wall penetration sleeves or rigid penetration flashing materials. Featuring a combined fastener and gasket/seal applied compression-force system that accomplishes simultaneous, solid, internal wall structure attachment and all-surface wall gasket mounting for long-term sustainable and effective air leakage sealing.
E-FLEX GUARD
– Insulation Protection for Refrigeration Piping on Outdoor applications. The Flexible PVC Insulation Protector complies with mandatory requirements where adhesive tapes are no longer allowed by code, and as specifically prescribed by the new Building/Residential/Energy Codes. Engineered PVC Material is UV/Weather Resistant and a Class II Vapor Retarder to comply with new energy codes, and sustainably protects outdoor pipe insulation (All-In-One).
Approved Product & Material Testing
ASTM E283
– Standard Test Method for Air Leakage
ASTM E331
– Standard Test Method for Water Penetration
ASTM D1525C-09
- Temperature Deformation Test
ASTM D648-07
- Temperature Load Deformation Test
ASTM D412
- Tension Deformation Test (UV Exposure & Water Immersion)
UL 94 HB
- Flammability Test
UL 746C
- Outdoor Suitability - f1 Rating
ASTM D573-04
- Deterioration Test
ASTM D746-07
- Brittleness Temperature Impact Test
ASTM G153
– Weatherization and UV Exposure
ASTM E96
– Water/Vapor Permeability
ASTM G21
– Anti-Fungal/Anti-Microbial
ASTM D412
- Tension Deformation Test (UV Exposure & Water Immersion)
ASTM D570
– Water Absorption
ASTM E84/UL 723
- Flame and Smoke Rating 25/450
Installation Applications
Exterior Vertical Walls:
Building Walls, Roof Parapet Walls, Roof Curb Walls, and Roof Service Walls
Thermal Insulation:
Any Outdoor Refrigerant Piping Insulation
Surfaces:
Stucco, Masonry, Concrete, Metal Paneling, Brick, Siding, and Roof Membranes
Size Range:
1/2" through 1" Wall thickness Insulation Piping
Installation Capability:
TGS Series with Larger Inside Cavity Feature Fits Over Wall Pipe Sleeves and Flashings
Applicable Equipment:
Designed for Central HVAC and Ductless Mini-Split System Applications
Codes & Standards Compliance
IECC 2012
- Protection of Piping Insulation – Commercial Section C403.2.8.1
IECC 2015
- Protection of Piping Insulation – Commercial Section C403.2.10.1
IRC 2018
– Refrigerant Line Insulation Protection – M1411.6.1 - Section N1103.4.1
California Building Energy Efficiency Standards (Title 24 Energy Code)
- Residential & Commercial Requirement for Pipe Insulation120.3 – Section: 150.0(j) 3a & b
California Building Energy Efficiency Standards (Title 24 Energy Code) 2016
- Residential & Commercial Requirement for Pipe Insulation120.3 – Section: 150.0(j) 2 & 3 – Section 150.0(m) 9
ANSI/ASHRAE/IESNA
Standard 90.1 - 2004, 2007, 2010
IBC
- 2006, 2009, 2012 Chapter 13
IRC
- 2006, 2009, 2012 Chapter 11 Part IV Energy Efficiency - Section N1101 General - N1101.1 Scope - Air Leakage Section N1102.4 Section N1102.4.1 - Building Thermal Envelope - (1. All joints, seams, penetrations) Chapter 11 Refrigeration Section 1101.0 Scope -1101.3 Protection
IECC
- 2006, 2009, & 2012 Air Leakage (Mandatory) - Residential Section 402.4.1 and 402.4.1.1 Building Thermal Envelope – Penetrations
IECC
- 2006, 2009, & 2012 Air Leakage (Mandatory) - Commercial Section C402.4.3 and C402.4.2 Building Thermal Envelope – Penetrations
IMC
- 2006, 2009, & 2012 Chapter 3 General Regulations Section 301.1 Scope – Sections 301.10, 301.11, 301.14, 301.15, 305.1, 305.2, 305.4
UMC
- 2006, 2009, & 2012 Chapter 11 Refrigeration – Section 1101.0 Scope - Section 1101.1 - General Requirements Section 1106.0 – Section 1106.2, Section 1111.0 Erection of Refrigerant Piping – Sections 1111.1, 1111.2, 1111.4
California Building Energy Efficiency Standards (Title 24 Energy Code)
- 2013 Air Leakage (Mandatory) - All Occupancies Section 117 Joints and other Openings/Exterior Wall Penetrations