Honeywell estop cable pull switch 2CPSA1A4B (2NO/2NC, 120VAC LED) MICRO SWITCH™*
$ 172.97
- Description
- Size Guide
Description
2CPSA1A4B: Dual span without broken/slack detection2CPS Series, Cable Pull Safety Switch, Cable, Maintained Both Sides, 2NC/2NO Direct Opening (Switch 2, Left: 1NC/1NO; Switch 2, Right:
1NC/1NO), 1/2 NPT, Gold-plated Contacts
Description
The 2CPS Cable Pull Safety Switch provides readily accessible emergency stop over a long, linear distance. It is a cost-effective means of providing this emergency stop signal compared to multiple emergency stop push buttons. (Cable Pull Safety Switches are not, however, to be used as a means of personnel safeguarding. They may be used to prevent further injury or damage to equipment when used for emergency stop signaling.)
The 2CPS Series Cable Pull Safety Switch is designed to provide emergency stop protection for exposed conveyor lines. The internal mechanism latches on both slackened cable (push) and pulled cable. This capability enhances productivity by eliminating nuisance stops due to variations in temperature, stretch of cable over time, and other application variables.
A line in the midpoint of the cable tension window indicates proper cable tension, providing easy and intuitive set-up. The direct acting switch contacts are held closed when the actuating cable is under proper tension and the reset knob is set to RUN. When the actuating cable is pulled, slackened or broken, a cam positively opens the NC (Normally Closed) switch contacts. The snap action, trip operation causes the switch contacts to change state and mechanically latch almost simultaneously when the cable is pulled, slackened or broken. The NC switch contacts remain open until the 2CPS is reset by properly tensioning the cable and manually rotating the reset knob.
When the direct acting switch contacts open, the auxiliary contacts also actuate (open contacts close and closed contacts open). The auxiliary contacts are electrically isolated from the direct acting switch contacts. These NO (Normally Open) contacts may be used for monitoring or signaling.
The 2CPS complies with: Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC; Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety function; IEC/EN60947-1; IEC/EN60947-5-1; IEC/EN60947-5-5; UL, CE, CSA, SIL 3 capable.
Features
Positive opening operation of normally closed contacts
Maximum cable length in a single direction is 76 m (250 ft) for a combined length of 152 m (500 ft) in dual directions
Choice of three actuator configurations
Removable contact block version available
Large wiring cavity with straight-through wiring
Gold-plated contacts are standard
Die-cast zinc housing
Optional hardware packs available
UL, CE, CSA, SIL 3 capable
Typical Applications
Long conveyor systems found in warehouses and distribution centers
Conveyor systems having a high amount of vibration
Conveyor systems that experience wide temperature swings
Long conveyor systems where easy through wiring, or highly visible trip status is required
Perimeter guarding where hos edown conditions are present
Typical Applications
Long conveyor systems found in warehouses and distribution centers
Conveyor systems having a high amount of vibration
Conveyor systems that experience wide temperature swings
Long conveyor systems where easy through wiring, or highly visible trip status is required
Perimeter guarding where hosedown conditions are present